Wholesale Discount Non Static Flooring - Anti-static conductive vinyl sheet – Linsu Detail:
1. ESD homogeneous vinyl floor has permanent anti-static function because it uses conductive static network formed at the interface of plastic particles along with the common homogeneous vinyl floor performance such as waterproof, flame retardant, wear resistant, sound absorption, chemical resistance etc.
2. PVC anti-static coiled floor, when it is grounded or connected to any lower potential point, enables the electric charge to be dissipated. It is characterized by a resistance between 10 2nd power and 10 9th power ohm. PVC anti-static coiled floor is made of polyvinyl chloride resin as the main body, plasticizers, stabilizers, fillers, conductive materials and coupling agents are made by scientific proportioning, polymerization and thermoplastic molding process, and the interface between PVC particles is formed Static electricity network, with permanent anti-static function. The floor looks like marble and has a good decorative effect. It is suitable for telecommunications, microelectronics, electronic industry program-controlled computer rooms, computer rooms, network floors, cleanliness and other places where precision instruments and equipment operate. The conductive material is a nano material with stable performance. The conductive material flows directly from the upper surface to the lower surface. This structure determines the permanence of the anti-static performance; the base material is a semi-rigid PVC material, which has the characteristics of wear resistance, flame retardancy and non-slip ,Meet the use requirements of various public large-flow places, with good compression resistance; It is a new type of light-body floor decoration material that is very popular in the world today, also known as “light-body floor material”. Advantages of PVC anti-static coiled floor material Beautiful scenery, can provide a variety of colors for users to choose; elastic, good foot feel; wear resistance, low dust generation, pressure resistance and flame retardant; corrosion resistance, weak acid resistance, weak alkali resistance. The product has been tested for anti-static performance before leaving the factory and meets the quality standards.
2m*20m homogeneous ESD vinyl floor roll
6mm*6mm homogeneous vinyl tile
The products conductive properties have been tested before and after production,in compliance with quality standards.
Characterstics | Standard | Unit | Result |
Type of flooring Marenal Cover |
ISO 10581-EN 649 | Homogeneous Sheet Polyvinyl chlonde majorization kingM |
Safety criteria
Flammability | GB 8624-2012 | class | Bl |
Slip resistance | DIN 51130 | group | R9 |
Dynamic coefficient of friction | EN 13893 | class | DS |
Performance behaviour
Sheet width |
ISO 24341-EN 426 |
m | 2 |
Sheet length |
ISO 24341-EN 426 |
m | 20 |
Overall thickness |
ISO 24346-EN 428 |
mm | 2.0 |
Total weight |
ISO 23997-EN 430 |
kg/m2kg/㎡ | 3.1 |
Wear resistance | EN 649 | group | T |
Dimensional stability |
ISO 23999-EN 434 |
- | X:<0.4%Y:<0.4% |
Color fastness | ISO 105-B02 | rating | >6 |
Resistance to staining | EN 423 | No Stain 0 | |
Bend resistance | GB/T 11982 2-2015 | no crack | |
Antibacterial | ISO 22196 | Class one | |
Anti iodine | Good | ||
Classification | |||
Domestic |
ISO 10874-EN 685 |
class | 23 heavy duty |
Commercial |
ISO 10874-EN 685 |
class | 34 very heavy duty |
Industnial |
ISO 10874-EN 685 |
class | 43 heavy duty |
Application
Anti-static floor is widely applied to electronic computer rooms, clean rooms, remote exchange rooms, manufacturing industry of electronic devices, workshops of microelectronic industry, asepsis rooms, central controlling rooms, and workshops which require purification and electronic proof. It is now widely used in banks, post offices, railway, medicine, and microelectronic industries.
600000 square meters standing stocks, 24000 square meters daily production.
Our flooring are packed carefully, to ensure the goods are delivered in good condition.
The installation
Conductive ESD floor should be installed on Sub floors that are leveled, smooth and free of cracks, Residual humibity should be under 2.5% tested with the CM Dumb test. Tiles,adhesive and installation site should reach a temperature of at least 18 at least 24 hours before installation.and paste the tiles with qualified conductive glue below 10 ohm for further details on installation methods.
Product detail pictures:
Related Product Guide:
Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for Wholesale Discount Non Static Flooring - Anti-static conductive vinyl sheet – Linsu, The product will supply to all over the world, such as: Anguilla, Johannesburg, Sudan, Our company's main products are widely used all over the world; 80% of our products exported to the United States, Japan, Europe and other markets. All stuff sincerely welcome guests come to visit our factory.
By Judy from Ghana - 2018.02.08 16:45
High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
By Jocelyn from Argentina - 2018.06.05 13:10